Add to Favorites
Share

KT-300S 8 zones Hot Runner Plastic Injection Temperature Controller Compatible with DME, Yudo, Athena, Tinko

  • Description
Product Detail

    Hot Runner Plastic Injection Temperature Controller Compatible with Dme, Yudo, Athena

    KT-300S Series hot runner temperature controller is single point control. The controller is assembled with single point temperature control cards. Each card only controls the temperature of one hot point. The display of control card can show preset temperature, actual temperature and alarm, and you may set temperature parameters via the display.

    300S 8zones hot runner controller(001).jpg

    8 zones

    Features:
    1. Inserted structure, easy to replace and repair.
    2. Real time cool-end compensation, when turn on, display real temperature of the environment.
    3. Accuracy: ±0.1?
    4. Heater and THERMOCOUPLE fault alarm
    5. High voltage alarm
    6. Three modes: automatic mode, manual mode and standby mode
    7. Two output mode: PID and PIDD
    8. Two types of THERMOCOUPLE: J and K
    9. TRIAC and RALEY series connection, double protection.
    10. Self testing when turn on.


    ??1.jpg


    Error code and solutions

    Fault

    Display

    Solutions

    Thermocouple breakage

    tC oPEn display tC alternately with oPEn

    Test the thermocouple with ohmmeter

    Thermocouple pinched

    tC SHrt display tC alternately with SHrt

    Find where the thermocouple is pinched

    Thermocpuple inverted

    tC rEu display tC alternately with rEu

    Check the thermocouple

    Thermocouple and heater swapped

    tC bAd display tC alternately with bAd

    Check the thermocoule and heater

    Scr breakage

    Scr bAd display scr alternately with bAd

    Test the Scr with ohmmeter

    The voltage is error

    HIGH voL display HIGH alternately with voL

    Check the the input voltage in cabinet

    Heater breakage

    HEAt oPEn display HEAt alternately with oPEn

    Test the heater with ohmmeter

    Heater pinched

    out SHrt display out alternately with SHrt

    Find where the heater is pinched

    Fuse breakage

    F1-2 brk display F1or2 alternately with brk

    Replace the fuse F1 or F2

    Order please tell
    1. circuit diagram(choose from A/B/C/D)

    ??2.png


    2. Wiring Diagram
    5pins connector:

    ??6.png

    16pins connector:

    ??7.png??8.png

    24pins connector:

    ??9.png

Send your message to this supplier
To:  

Suzhou Kylin Electronic Technology Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  

  
Not exactly what you want? One request, multiple quotations Get Quotations Now >>